Multichannel Datalogger is a highly versatile and economical Data logger having Analog Inputs with Pendrive (USB) Facility and RS232 port for communication.
It can be used as :
1) Standalone Datalogger
2) Datalogging and Alarm annunciator
3) Datalogger with ON/OFF Control
4) Datalogging in Ofline mode and analog input model with SCADA Connectivity
FALCON 1600 DL is 4,8,16 channel input data logger which has very high logging memory so data of several days can be recorded. Analog input to FALCON 1600 DL can be mA / RTD (PT100, 3 wire) / Thermocouple or Voltage. Recorded data can be transferred to PC through RS232 port in Excel file. Auto-Printout of data can be taken online at a settable print interval or manually you can take printout of all data which is recorded.Control outputs can be used with external relay module for control. The status is indicated on front LEDs. In-built pen-drive interface is provided for data downloading /recording. 4GB pen drive can be connected which is equivalent to 100 million readings per channel. Unique Backup Recovery feature allows you to recover lost data during communication failure.
Data logger is used in many industries such as Pharma,foundary, Steel, Power, Cement, Water Pumping Stations, Educational Institutes, R & D labs.
Technical Specifications | ||
Input | RTD Pt100 (3wire); 4 - 20 mADC; DCVolt - 1V, 4V; Thermocouples J,K,R,S,T,B,E fixed for each 4 channels. (Combination factory set) | |
Channels | Max 16 Channels in step of 4 Channels. | |
Display | 7 Segment RED LED, 2 - Digit Channel no. 5 - Digit Process Value including sign. |
|
Data logging | Internal memory: Realtime data logging of 13440 readings per channel External memory : 100 million readings stored on pendrive. Logging interval Min/ Sec. Data logging Enable / Disable facility is available. Optional Data backup facility for SCADA application |
|
Printing |
Auto/ Manual Printing- Centronics compatible parallel printer port for DOT matrix printer. Print interval 1 to 240min. |
|
Serial Port | RS232 port with ASCII Protocol. Optional- RS485 with MODBUS RTU protocol with / without backup recovery. | |
Alarm Output |
One common alarm relay output, contact rating 230 VAC,1 Amp. | |
Control Output ( Optional ) |
Digital output for each channel working on individual HI/LO limits To be used with external relay module.- Hi/Lo limits for each channel are programable through keyboard |
|
Cabinet | Panel mounting type: Bezel: 96 x 192mm (H x W) Depth: 195 mm Cutout: 92 x 186 mm (H x W) |